A joint torque sensor measures one number. A six-axis force/torque sensor measures all six: three forces and three moments passing through a wrist or an ankle. Humanoids typically carry four of them, and they are what lets a robot find the centre of pressure under its foot or feel how hard a hand is pushing. Prices are falling fast as Chinese suppliers scale up.

4
Six-axis sensors in a typical humanoid: one per wrist, one per ankle. Optimus Gen 2 carries four
<¥5k
Reported price of Fourier’s optical sensor, against about ¥10,000 for comparable parts (insider figure)
80%+
Link-touch’s share of China’s humanoid six-axis sensor market in 2025, per CCID
1.2M
Forecast Chinese shipments of humanoid six-axis sensors in 2030, worth about ¥6 billion

Sources: 36Kr (Sept 2025); Yicai Global (July and Dec 2025); CCID 2026 China Humanoid Robot Six-Axis Force Sensor Market Research Report, via Tonghuashun.

Six numbers from one piece of metal

Any load passing through a rigid connection can be described by six components: forces along x, y and z (Fx, Fy, Fz) and moments about the same three axes (Tx, Ty, Tz). A six-axis force/torque (F/T) sensor is a flange-shaped part bolted into that connection, between forearm and hand or between shin and foot, that reports all six at once. The joint torque sensors found inside some actuators measure only the moment about their own axis.

The classic design is a machined elastic body: a hub and an outer ring joined by spokes that bend slightly under load. Strain gauges bonded to the spokes are wired into bridges, and each bridge voltage responds to a mix of the six load components. A calibration matrix, measured by loading the sensor with known weights and moments, converts the bridge signals into the six outputs. Whatever the matrix fails to separate shows up as crosstalk: a pure Fz load that leaks into the Tx reading, for example. ATI’s Mini45, a common research sensor, is cut from high-strength stainless steel by wire EDM and uses silicon strain gauges, which ATI says give a signal 75 times stronger than foil gauges.

Figure 1 · How a strain-gauge six-axis sensor turns bending into six numbers

Elastic body: hub, spokes, outer ring Strain gauges, wired into bridges Hub bolts to the hand or foot; outer ring to the limb FZ · TZFX · TXFY · TY F = force along an axis · T = moment (torque) about it Bridge signalsv1 … vn Calibrationmatrix C Fx Fy FzTx Ty Tz Crosstalk: a load on one axis that leaks into another output. Calibration aims to cancel it.

Illustration: humanoid.guide. Simplified spoke-type body; commercial sensors use different body shapes and more gauges per spoke. Not a specific product.

At the ankle: finding the centre of pressure

A walking robot has to know where the ground is pushing on its foot. That point, the centre of pressure, coincides with the zero moment point when the foot is flat, and balance controllers try to keep it inside the sole. An ankle F/T sensor gives it directly: the vertical force Fz and the two tipping moments Tx and Ty locate the point on the sole, and the shear forces Fx and Fy correct for the sensor sitting a height d above the ground. In the standard textbook form, the centre of pressure lies at x ≈ (−Ty − Fx·d) / Fz and y ≈ (Tx − Fy·d) / Fz, although sign conventions differ between robots.

The same sensor tells the controller when the foot touches down, how the weight is split between the two legs and whether the robot is being pushed. 36Kr describes six-axis sensing as the core of dynamic balance: the readings let a robot adjust its gait to avoid a fall. The catch is impact. A KAIST team designing a foot sensor for legged robots notes that landing shocks pass straight into the sensor’s spring structure, that strain gauges often break under them, and that many commercial walking robots therefore use simple one-axis pressure sensors in their feet instead. They recommend sizing a foot sensor for three to five times the robot’s ground reaction forces.

Figure 2 · Animated · The centre of pressure rolls from heel to toe during stance

Ankle F/T sensor (above the sole, height d) HEELTOE walking direction (x) Centre of pressure CoP x ≈ (−Ty − Fx·d) / FzCoP y ≈ (Tx − Fy·d) / Fz Schematic. Real paths curve and vary with gait; sign conventions differ between robots.

Illustration: humanoid.guide, standard centre-of-pressure relations for a sensor mounted at height d above the sole. CSS animation; shown static when reduced motion is requested.

At the wrist: feeling the load in the hand

Between forearm and hand, the sensor sees the weight of whatever the robot is holding and every contact force the hand makes. That lets a controller check a payload, limit grip and push forces, slide a part into a slot by feel, or stop when the hand meets something it did not expect. It complements the tactile arrays in the fingers rather than replacing them: tactile sensors say where on the hand contact happens, and the wrist sensor gives the total force and moment.

Yicai reports that Ubtech, X-Humanoid, Spirit AI and Tesla have installed six-axis sensors at wrists and ankles, and that Optimus Gen 2 uses four among more than 30 sensors in total; coverage of Tesla’s Gen 2 launch listed foot force/torque sensing among its upgrades. Not every robot has them. Fourier’s GR-2 specification lists a 6-axis IMU and array tactile sensors in the hands, but no six-axis F/T sensors, and many low-cost humanoids estimate contact from motor current. A Chinese robotics engineer quoted by Yicai expected six-axis sensors to move from optional to standard equipment in 2026.

Range, overload and mass: reading the spec sheet

A humanoid sensor has to measure small forces precisely and also survive large ones, which is why overload rating matters as much as measuring range. ATI’s Mini45 reads Fz up to 1,160 N in its largest calibration but tolerates 10,000 N in a single axis, about 8.6 times its range. The Mini85, which ATI announced in 2018 for humanoid ankles, reads up to 3,800 N and tolerates 27,000 N, about 7.1 times. Its weight, 635 g, is a real cost at the end of a leg. Both research prototypes from KAIST are much lighter for similar ranges.

Table 1 · Published six-axis sensors relevant to humanoid wrists and ankles

SensorPrincipleFz rangeTx/Ty rangeFz overloadMassSize
ATI Mini45 (SI-580-20)Silicon strain gauge±1,160 N±20 N·m±10,000 N92 gØ45 × 15.7 mm
ATI Mini85 (SI-1900-80)Silicon strain gauge±3,800 N±80 N·m±27,000 N635 gØ85.1 × 29.8 mm
KAIST optical foot sensor (prototype)Photoreflectors on one PCB±1,850 N±25 N·m—79 gØ56 × 18 mm
KAIST inductive sensor (prototype)PCB coils, eddy current±1,435 N±27 N·m—280 gØ85 × 36 mm
Haptron ankle sensorOptical, 3D-printed steel body8,000 N / 500 N·m (axes not stated)300%——

Sources: ATI Mini45 and Mini85 calibration pages (mass includes interface plates); Kim, Choi & Kim, arXiv 2309.04720 (mass includes plate and cable); Kim & Kim, arXiv 2505.09069; Metrology News on Haptron Scientific. — means not published in these sources.

Chart 1 · Rated Fz range of the four sensors with full specifications, in newtons

01,0002,0003,0004,000 RATED FZ RANGE (N) ATI Mini45 KAIST inductive KAIST optical ATI Mini85 92 g280 g79 g635 g 1,160 1,435 1,850 3,800

Sources: ATI Mini45 (SI-580-20) and Mini85 (SI-1900-80) calibration pages; arXiv 2309.04720; arXiv 2505.09069. Scale 0.12 px per newton; masses as in Table 1.

Beyond strain gauges: optical and inductive sensing

Bonded gauges are the expensive, fragile part of a conventional sensor: they are applied by hand, need a bridge, amplifier and data acquisition chain, and degrade under repeated impacts, according to the KAIST authors. Newer designs keep the elastic body but measure its deflection without contact. The KAIST optical prototype uses six photoreflectors on a single circuit board, samples at 5 kHz, weighs 79 g and costs under $250 in parts; its mean full-scale errors run from 0.085% to 0.51% per axis and its worst crosstalk is 3.1%. The team’s 2025 inductive version reads coil frequency shifts and reports crosstalk mostly below 0.3%, with a maximum of 0.72%.

Industry is moving the same way. Fourier’s humanoid sensor, launched in late 2025, detects deformation through an optical path rather than strain gauges and is calibrated largely by automated equipment; an insider told Yicai it costs under ¥5,000, about half the price of comparable parts. Haptron Scientific prints its sensor bodies in metal with partner BLT, getting 15 to 30 sensors from one build plate instead of machining them one at a time.

The supply side: one dominant Chinese supplier

Six-axis sensors were long an imported, ATI-dominated product. China’s humanoid boom changed that quickly. Domestic shipments of six-axis sensors passed 10,000 units in 2024, and the localisation rate for Chinese humanoids rose from 19% to 57.8% in four years, according to MIR figures cited by 36Kr. By 2025, a CCID report published in August 2026 put the top three suppliers at 92.8% of China’s humanoid six-axis market, with Link-touch (蓝点触控, also rendered BlueDot Touch) above 80%, Kunwei at 9.2% and Yuli Instruments at 3.3%.

Chart 2 · Share of China’s humanoid six-axis force sensor market, 2025

0%25%50%75%100% MARKET SHARE, 2025 Link-touch Kunwei Yuli Instruments All others (implied) >80% 9.2% 3.3% ≈7%

Source: CCID, 2026 China Humanoid Robot Six-Axis Force Sensor Market Research Report (Aug 2026), via Tonghuashun. Link-touch bar drawn at 80.3%, the remainder of the 92.8% top-three total; ‘all others’ is 100% minus 92.8%.

Link-touch shipped nearly 70,000 sets of force/torque sensors in the first half of 2025, more than in all of 2024, and raised a Series B of nearly ¥100 million in July 2025; its customers include Xiaomi Robotics and ABB. Kunwei closed a Series B of several hundred million yuan in February 2025 with Xiaomi and Hillhouse among the investors. Donghua Testing raised ¥150 million for trial production, and Jiuding Investment agreed to buy 53.29% of Nanjing Shenyuansheng for ¥213 million. Yicai reported production costs down 30% in 2025, while noting that most sensors are still customised for each robot maker because there is no common standard.

CCID’s 2030 forecast of 1.2 million units worth about ¥6 billion implies an average of roughly ¥5,000 per sensor, the price Fourier is reported to charge today. Four sensors per robot at that price is about ¥20,000, a meaningful line in any humanoid bill of materials.

What to ask a supplier

  • Range and overload, per axis. A foot sensor needs headroom for landing impacts, several times body weight, not just standing load.
  • Crosstalk and full-scale error. Ask for the full calibration report, not a single accuracy figure, and check whether full scale means the stated range or twice it.
  • Mass, height and bore. Every gram at the ankle or wrist adds inertia, and the stack height pushes the hand or foot further from the joint. A through-hole lets cables pass.
  • Interface and sample rate. Integrated electronics with a digital bus such as CAN-FD or EtherCAT avoid long analogue cables; balance control needs readings at hundreds of hertz or more.
  • Temperature drift and recalibration. How the zero moves as the joint heats up, and how it is re-zeroed in service.

Go deeper: The Humanoid Actuation Report

249 pages on motors, reducers, screws, bearings, encoders and drives, the vendors behind every major platform, and the cost curves that decide adoption to 2036.

The Humanoid Actuation Report All joints & actuators articles All humanoid.guide reports

FAQ

What does a six-axis force/torque sensor measure?

The three forces (Fx, Fy, Fz) and three moments (Tx, Ty, Tz) passing through the point where it is mounted. A joint torque sensor, by contrast, measures only the moment about one joint axis.

Where are six-axis sensors fitted in a humanoid?

Usually at the two wrists and the two ankles, four in total. Tesla’s Optimus Gen 2 is reported to carry four; Ubtech, X-Humanoid and Spirit AI also fit them at wrists and ankles. Many lower-cost robots leave them out and estimate forces from motor current.

Why does an ankle sensor help a robot balance?

From the vertical force and the two tipping moments it gives the centre of pressure under the foot, which balance controllers keep inside the sole. It also detects touchdown and how weight is shared between the legs.

How much does a six-axis sensor cost?

Chinese humanoid-grade sensors were around ¥10,000 in 2025, according to an insider quoted by Yicai, with Fourier’s optical sensor reported below ¥5,000. CCID’s 2030 forecast implies an average near ¥5,000.

Who makes them?

In China, Link-touch held more than 80% of the 2025 humanoid market, followed by Kunwei (9.2%) and Yuli Instruments (3.3%), according to CCID. ATI is the long-established Western supplier; newer entrants include Fourier and Haptron Scientific.

Sources