Joint Brakes in Humanoid Robots: What Holds the Robot When the Power Goes
Joint brakes: what holds a humanoid when the power goes
An industrial arm that loses power simply freezes: spring-applied brakes in every joint clamp shut and the arm stays where it was. A walking humanoid cannot do that. Cut its power and it falls. That one fact turns the humble holding brake, a component most robot buyers never think about, into one of the harder design problems in humanoid safety.
Sources: KEB America (flat-profile brakes); Design World (power-off brake options); Motion Control Tips (miniature brakes).
The fail-safe assumption that breaks on two legs
Classical machine safety rests on a simple idea: if something goes wrong, remove the energy. Industrial robots are built around it. Every axis carries a power-off brake, and the safe state is the de-energised state. A 2026 feasibility study on certifying industrial humanoids calls this assumption “fail-passive”, and argues that it inverts on a biped: “Removing power from a walking biped produces an uncontrolled fall, which is itself a hazard.” For a humanoid, the safe state is an actively balanced standstill, and that needs power, sensors and a working control policy.
The risk is concrete. Agility Robotics’ Digit, a 1.8 m, 65 kg machine by MIT Technology Review’s figures, collapsed on a trade-show floor while handling totes in 2025. Industry guidance on the ISO 25785-1 draft puts rough numbers on the hazard: a 1.7 m robot moving at 1.5 m/s could land within about two metres, depending on speed, load and floor angle. That is the zone brakes, controllers and stop logic have to shrink.
Where the brake sits in a joint
In a rotary joint module the brake almost always sits on the motor side, at the rear of the motor shaft next to the encoder, before the reducer. That placement is a matter of leverage. A brake on the high-speed shaft only has to hold motor torque, and the reducer multiplies it. As an illustration, a 5 N·m brake behind a 50:1 reducer can hold on the order of 250 N·m at the joint output, before losses. A brake on the output side would need the full joint torque in one disc. The catch is that the reducer’s teeth and flexspline stay in the load path when the brake holds, so a hard fall onto a locked joint loads the gearbox as well as the brake.
Figure 1 · Where the holding brake sits in a typical rotary joint module (schematic section)
Illustration: humanoid.guide. Schematic only, not to scale. Layouts vary by supplier; some modules omit the brake entirely.
Spring-applied or permanent magnet
Two electromagnetic designs dominate robot joints. Both are power-off brakes: they hold when de-energised and release when current flows. In a spring-applied brake, springs press an armature plate against a friction rotor, and an energised coil pulls the armature back to free the shaft. In a permanent-magnet brake, a magnet holds the armature against the hub, and current in the coil cancels the magnet’s field to release it.
Figure 2 · Animated · Spring-applied brake cycle: coil energised = released, power off = springs clamp
Illustration: humanoid.guide, simplified from the spring-applied principle described by Design World and Kendrion. Real air gaps are fractions of a millimetre.
The trade-offs matter more in a humanoid than in a factory arm. Permanent-magnet brakes offer near-zero backlash and the most torque in the smallest package, but Design World notes they are usually specified for holding only, need a steady current within roughly ±10% of rated voltage, and are sensitive to temperature. Spring-applied brakes have a little play between rotor and hub, but they tolerate dynamic stops, run on friction linings that wear slowly, and need only about a quarter of their pull-in voltage to stay released. For a robot that must hold every brake open all day on a battery, that last point counts.
Table 1 · Joint brake types compared
| Type | How it holds | Backlash | Power while released | Dynamic stops | Watch-outs |
|---|---|---|---|---|---|
| Spring-applied | Springs clamp armature onto a friction rotor | Small, from rotor-to-hub fit | Can drop to about 1/4 of pull-in voltage | Rated for stopping and holding | Thicker, more parts; friction lining wears |
| Permanent magnet | Magnet pulls armature onto the hub; coil cancels the field | Near zero | Steady current, about ±10% voltage window | Usually holding only | Temperature-sensitive; holding torque can fade with oxidation |
| Mechanical latch (research) | Solenoid pin locks a toothed or latched ring; springs absorb the impact | Discrete lock positions | Solenoid only | Tested for Category 0 stops | Locks at set angles, not anywhere |
Sources: Design World, ‘An inside look at electromechanical power-off braking options’; Mechatronics (Elsevier), ‘Safe robot joint brake based on an elastic latch module’, tested over 1,000 Category 0 stops.
Thin, light and cheap to hold open
Brake suppliers now pitch at humanoids by name, and the selling point is thickness. KEB makes the case plainly: a humanoid hip module has to fit motor, gearbox, encoder, drive electronics and holding brake inside the width of a human hip. Its COMBISTOP S1 Flat brakes are 12 to 15 mm thick with 3.4 to 10.8 N·m of holding torque over two sizes, a large bore for cables through the joint axis, and no rare-earth magnets. Kendrion’s slim permanent-magnet line spans 2.7 to 17 N·m, and Miki Pulley’s BXR spring-applied brakes claim about two-thirds the thickness of standard designs.
Chart 1 · Rated holding-torque range of compact robot joint brake lines, N·m (motor side)
Sources: Miki Pulley robotic-arm brakes; Kendrion brake technology for robotics; KEB America. Catalogue ranges across all sizes in each line. Motor-side torque; the reducer ratio multiplies it at the joint output.
Power is the other budget. Every spring-applied or permanent-magnet brake draws current for as long as the joint moves. KEB puts a 12-joint battery robot at 40 to 50 W just to hold its brakes open, and recommends dropping the coil voltage after release. Miki Pulley’s small BXR-LE pulls in at 24 VDC and holds at 7 VDC. At the miniature end, Motion Control Tips describes a 7 g brake that releases at about 4 W and stays released at 0.34 W. Across 30 or more joints, those watts come straight out of runtime, which is one reason brake choice is made joint by joint, not robot-wide.
Stopping without falling
Brakes alone do not make a humanoid safe to stop. The industry answer, so far, is to decide how the robot stops, and let brakes cover the case where everything else has failed.
- Category 0: power off now. The classic industrial stop. On a biped it produces the uncontrolled fall that makes the fail-passive model break down, unless the joints lock in a stable pose.
- Category 1: stop, then cut power. This is what Agility adopted for Digit’s emergency stop, according to heise: actuators keep power long enough for the robot to “stop gently and safely without falling over”, behind a safety PLC rated Performance Level d and FailSafe over EtherCAT.
- Controlled descent. Digit’s newer behaviour puts down what it carries and drops to its hands and knees before powering down, per MIT Technology Review. Guidance on the ISO 25785-1 draft calls this kind of kneeling posture a zero-energy pose.
- Brakes as the last line. The Association for Advancing Automation argues that if other safety systems malfunction, “mechanical joint brakes must prevent a full collapse”, while stressing that no single component is enough.
The standards are catching up. ISO 25785-1, covering industrial mobile robots with actively controlled stability (legged, wheeled or otherwise), was still a committee draft in 2026. Summaries of the draft say it asks for controlled descent rather than collapse, warnings before power loss where possible, and defined behaviour when an emergency stop is triggered. Industry estimates put publication in late 2026 or 2027. Wheeled humanoids sit in an easier place: as A3 notes, they stop rather than fall.
What to ask a supplier
Humanoid makers rarely publish which joints carry brakes, so buyers and integrators should ask. Useful questions: which joints are braked (arms holding a payload and the hip and knee pitch axes matter most), whether the brake is rated for dynamic stops or holding only, the holding torque at the joint output after the reducer, the power drawn to keep all brakes released, and what the robot does on an emergency stop and on a sudden loss of battery power. The answers say more about deployment readiness than a peak-torque figure does.
Go deeper: The Humanoid Actuation Report
249 pages on motors, reducers, screws, bearings, encoders and drives, the vendors behind every major platform, and the cost curves that decide adoption to 2036.
The Humanoid Actuation Report All joints & actuators articles All humanoid.guide reportsKeep reading · Joints & actuators
Related articles
FAQ
Do humanoid robots have brakes in their joints?
Some joints do, but makers rarely publish which. Brake suppliers such as KEB now sell flat-profile brakes aimed at humanoid joints, and braked joint modules are widely available. Unlike industrial arms, where every axis is braked by default, humanoid designers weigh each brake against its thickness, mass and power draw.
Why does a humanoid fall when its power is cut?
A walking humanoid is dynamically stable: its motors are constantly working to keep it balanced. Remove power and that control stops, so the robot collapses unless its joints lock in a stable pose. That is why the usual industrial response, cutting power, is itself a hazard for bipeds.
What is the difference between a spring-applied and a permanent-magnet brake?
Both hold when unpowered. A spring-applied brake uses springs to clamp a friction rotor and a coil to release it; it has slight backlash but is rated for dynamic stops and can hold open at about a quarter of its pull-in voltage. A permanent-magnet brake uses a magnet to hold and a coil to cancel it; it is more compact with near-zero backlash, but is usually for holding only and is more sensitive to voltage and temperature.
What does ISO 25785-1 require on power loss?
ISO 25785-1 was still a draft in 2026. Summaries of the draft say it asks for controlled descent rather than collapse, warnings before power loss where possible, and defined behaviour on an emergency stop. Final publication is expected in late 2026 or 2027.
Why is the brake on the motor side, not the output?
On the motor side the brake only has to hold motor torque; the reducer multiplies it at the output. A small, thin brake can therefore hold a large joint torque. The downside is that the reducer stays in the load path when the brake is holding.
Sources
- Toward Certified Functional Safety for Industrial Humanoid Robots: The Fail-Passive Gap and a Feasibility Study (arXiv:2608.02809) (fail-passive assumption; uncontrolled fall on power removal)
- KEB America: Thin is the New Strong, flat-profile brakes for humanoid, collaborative and exoskeleton robots (12–15 mm, 3.4–10.8 N·m, 40–50 W for 12 joints)
- Design World: An inside look at electromechanical power-off braking options (spring-applied vs permanent-magnet trade-offs)
- Kendrion: Brake technology for robotics (permanent-magnet and spring-applied torque ranges)
- Miki Pulley: Brakes for robotic arm applications (BXR and BXR-LE ranges, 24 V pull-in / 7 V hold)
- Motion Control Tips: Miniature spring-applied brakes (7 g brake, 4 W release, 0.34 W hold)
- Mechatronics: Safe robot joint brake based on an elastic latch module (latch brake, 1,000 Category 0 stops)
- heise online: Agility Robotics increases the safety of its humanoid robot Digit (Category 1 stop, PLd safety PLC, FSoE)
- MIT Technology Review: Why humanoid robots need their own safety rules (Digit fall; kneel before power-down)
- A3: Safety by design, how humanoid robots must evolve to depart the walled garden (brakes to prevent collapse; wheeled robots stop rather than fall)
- ISO/CD 25785-1: Safety requirements for dynamically stable industrial mobile robots (standard status)
- i-SCOOP: ISO 25785-1 explained (controlled descent, fall zones, timeline)