Electro-Hydrostatic Actuators in Humanoid Robots: Hydraulic Force Without the Valve
Electro-hydrostatic actuators: hydraulic force without the valve
An electro-hydrostatic actuator, or EHA, gives every joint its own small electric motor, pump and cylinder in a sealed oil loop. There is no central pump and no servo valve. The idea promises hydraulic force density with the efficiency and back-drivability of an electric joint. A University of Tokyo team built a whole 40-joint humanoid on it, and a handful of labs and start-ups still pursue it. No production humanoid uses it yet.
Sources: Ko 2018 (University of Tokyo thesis); Zhao et al. 2023; Kaminaga et al. 2009.
What an electro-hydrostatic actuator is
A classic hydraulic humanoid, like the hydraulic Atlas that Boston Dynamics retired in 2024, works like a small excavator. One pump keeps a supply line at high pressure. At every joint, a servo valve meters that pressure into a cylinder. The valve is what controls the joint, and it does so by throttling: it lets through only part of the available pressure and turns the rest into heat.
An EHA moves the power source into the joint. A brushless motor turns a small reversible pump. The pump’s two ports connect straight to the two chambers of a double-acting cylinder, or to a rotary vane motor. Turn the motor one way and oil flows into one chamber and out of the other, and the piston moves. Reverse the motor and the piston reverses. The oil never leaves the loop, so there are no supply hoses running through the body. Only electrical power and data reach the joint, as in an electric humanoid.
Figure 1 · Animated · The closed oil loop inside an EHA
Illustration: humanoid.guide, after Kaminaga et al. 2009 and Ko 2018. Piston travel shown proportional to pump rotation (leakage ignored). CSS animation; static when reduced motion is requested.
How the pump replaces the gearbox
An electric joint needs a reducer because a motor is fast and weak. An EHA uses the oil as its reducer. Each pump revolution moves a fixed volume of oil, its displacement. The motor torque needed scales with pressure times displacement, while the piston force is pressure times piston area. A pump with a tiny displacement driving a much larger piston gives a large effective ratio, set by geometry rather than by gear teeth. Kaminaga’s 2009 knee EHA reached a reduction of about 100:1 this way.
The same relation makes force easy to measure. Pressure sensors on the two lines give the piston force directly, which lets an EHA close a fast inner pressure loop without a separate torque sensor. Hydra’s linear EHA delivers 1,500 N at 5.25 MPa of differential pressure, which works out to about 2.9 cm² of effective piston area. Its maximum piston speed is about 150 mm/s.
Why drop the servo valve
Servo-valve hydraulics give the highest torque density of any actuator type, and they gave Atlas its jumps and backflips. The cost is energy. The central pump must hold the whole system at supply pressure whether or not a joint needs it, and every valve throttles the difference. A 2023 paper from the Beijing Institute of Technology puts valve-controlled cylinder transmission efficiency below 30%. It claims an EHA can exceed 70% because there is no throttling loss. Treat both as design-level figures, not a side-by-side measurement.
Boston Dynamics worked around the problem with custom valves. Speaking at the 2018 IFK fluid power conference, engineering VP Aaron Saunders described valves with a braking mode for negative work and a coasting mode that moves oil chamber to chamber. Each of the 80 kg robot’s 28 degrees of freedom ran force control. The EHA takes the opposite route: it removes the shared high-pressure supply entirely.
Table 1 · Three ways to power a humanoid joint
| Feature | Valve-controlled hydraulics | Electro-hydrostatic (EHA) | Electric motor + reducer |
|---|---|---|---|
| Power source | Central pump and accumulator | Motor and pump at each joint | Motor at each joint |
| Control element | Servo valve throttles pressure | Motor speed and torque | Motor current |
| Wiring to joint | High-pressure hoses plus signal | Power and data only | Power and data only |
| Transmission efficiency | Below 30% (cited) | Above 70% claimed; 40% peak measured on Hydra’s linear EHA | Depends on reducer |
| Force sensing | Pressure sensors | Pressure sensors | Current, or a torque sensor |
| Humanoid example | Hydraulic Atlas (retired 2024) | Hydra (research); KALYSTA (in development) | Most production humanoids |
Sources: Zhao et al. 2023 (efficiency figures as stated, not measured side by side); Ko 2018 (40% peak efficiency); Fluid Power World 2018; Kaminaga et al. 2017; Université Paris-Saclay 2025.
Hydra: a whole humanoid on EHAs
The most complete EHA humanoid is Hydra, built by Yoshihiko Nakamura’s group at the University of Tokyo and shown at the ISER 2016 symposium. It is 1.80 m tall, weighs 130 kg and has 40 joints. They are driven by 24 double-rod linear cylinders and 8 vane motors, fed by 36 water-cooled trochoid pumps. Each hand uses a five-DoF cluster EHA. Multi-axis joints use parallel mechanisms so that several cylinders share the load.
Tianyi Ko’s 2018 thesis documents the result. Joint position and torque control reached roughly 30 to 40 Hz bandwidth. Hydra walked with a 0.2 m stride and 1 s steps, and it absorbed pushes on its limbs through compliant whole-body control. Its pressure loop reached 100 Hz with the piston held fixed, which the thesis reports as higher than earlier EHA and series elastic actuator results.
Back-drivability: the knee test
The Tokyo group’s motive was back-drivability: a joint that yields when pushed, so a robot can absorb contact. Oil flowing through a pump has little friction compared with a high-ratio gear train. In 2009, Kaminaga and colleagues compared a knee EHA with a Harmonic Drive CSG40-100 of almost the same size. The EHA was 130 mm across and weighed 2.0 kg, with 1,988 N·m allowable torque. The strain-wave gear was 135 mm across, weighed 1.7 kg and was rated at 2,700 N·m.
On back-driving torque, the result was mixed. The EHA’s output side measured 4 N·m, close to its 3.7 N·m datasheet estimate. The total measured figure was 14 N·m, which the authors put down mainly to oil-seal friction, against about 7.4 N·m for the gear with an assumed motor friction. The authors expected a design change to halve that figure, and aimed for a 50 to 100 times reduction long term. Ko’s later actuators attacked seal friction with thin double rods and active friction compensation.
Chart 1 · Back-driving torque, knee EHA vs strain-wave gear of similar size, N·m
Source: Kaminaga, Ono, Nakashima & Nakamura, ICRA 2009. Gear-plus-motor figure assumes 45 mN·m motor friction, as in the paper. Bars drawn at 25 px per N·m.
Published EHAs for legged robots
Outside Tokyo, EHA work has moved toward heavier machines and new layouts. Pressures range from under 1 MPa in Sherbrooke’s low-pressure legs to 30 MPa in a wheel-legged knee. That spread matters, because pressure decides how small the cylinder can be and how hard the seals work.
Table 2 · Published electro-hydrostatic actuators for humanoid and legged robots
| Actuator or robot | Year | Layout | Key figure | Other published data |
|---|---|---|---|---|
| Univ. of Tokyo knee EHA | 2009 | Trochoid pump, vane motor, ~100:1 | 1,988 N·m | 130 mm, 2.0 kg; 14 N·m total back-drive torque |
| Hydra linear EHA | 2018 | Double-rod cylinder, beam structure | 1,500 N | ~150 mm/s; 100 Hz pressure bandwidth; ~40% peak efficiency |
| Hydra humanoid | 2016 | 24 cylinders, 8 vane motors, 36 pumps | 40 joints | 130 kg, 1.80 m; 30–40 Hz joint bandwidth |
| BIT wheel-legged knee EHA | 2023 | Pump rated 30 MPa, cylinder | 9,400 N | 3.69 kg; over 2,518 N/kg; force step in 39–50 ms |
| Sherbrooke reconfigurable legs | 2025 | Ball-screw leader piston, valves share one motor | 366 N | Per leg, at about 0.77 MPa; 4.8× less main-motor power walking than a fully actuated baseline |
| KALYSTA joint module | 2025 | Motor, micropump, piston per joint | 2.5 kg | 4 × 4 × 8 cm; company claims it moves one tonne at 20 cm/s |
Sources: Kaminaga et al. 2009; Ko 2018; Kaminaga et al. 2017; Zhao et al. 2023; Denis et al. 2025; Université Paris-Saclay 2025 (company claims, not independently verified).
The Beijing Institute of Technology knee EHA shows how high pressure buys force density. At its 30 MPa rating it produced 9,401 N from 3.69 kg, a force-to-weight ratio above 2,518 N/kg, against the 1,424 N/kg the same paper lists for Hydra’s actuator. In Canada, the Université de Sherbrooke takes the opposite approach: low pressure, and motorised valves that let one motor serve both legs. In France, KALYSTA Actuation, spun out of Université Paris-Saclay’s IBISC lab, is building a decentralised electrohydraulic humanoid and targets a full demonstrator in 2029.
The catch
Shrinking an EHA to humanoid scale works against it. Ko’s thesis found that miniaturisation raises internal leakage and cuts output force. Its remedies were tighter gaps, more viscous fluid, reinforced casings and water-cooled pump housings. Seals add friction that the gearless design was meant to remove. Every joint carries its own pump, oil volume and pressure sensors, and the oil adds weight on top of the motor. Hydra’s linear EHA peaked at about 40% efficiency, well short of the 70% cited as an EHA’s potential.
Commercial humanoid makers have gone the other way. Electric joints with strain-wave, planetary or roller-screw transmissions now dominate production robots, and the electric Atlas replaced the hydraulic one. We found no humanoid in commercial production that uses EHA joints. A 2025 review in China’s Journal of Mechanical Engineering still names legged robots as a key EHA application. Hydraulics suppliers such as Domin also pitch EHAs for hips, knees and shoulders, where the loads are highest.
- Watch force-to-weight at humanoid scale. The 2,500 N/kg figures come from heavy wheel-legged robots. Ask what an EHA weighs at the force a 60 kg humanoid’s knee needs.
- Ask for measured efficiency. Claims of 70% and more are common. Published humanoid-scale measurements are closer to 40% at peak.
- Ask about seals and leakage over life. Seal friction set the back-drive torque in the Tokyo knee, and seals wear.
Go deeper: The Humanoid Actuation Report
249 pages on motors, reducers, screws, bearings, encoders and drives, the vendors behind every major platform, and the cost curves that decide adoption to 2036.
The Humanoid Actuation Report All joints & actuators articles All humanoid.guide reportsKeep reading · Joints & actuators
Related articles
FAQ
What is an electro-hydrostatic actuator?
An actuator in which an electric motor drives a small reversible pump connected directly to a cylinder or vane motor in a closed oil loop. Motor direction sets the direction of motion and motor torque sets the pressure, so no servo valve or central hydraulic pump is needed.
How is an EHA different from the hydraulics in the old Atlas?
The hydraulic Atlas used a central pump and a servo valve at each joint that throttled supply pressure. An EHA puts a motor and pump at each joint, so only electrical power reaches it and there is no throttling loss.
Has a humanoid robot been built with EHAs?
Yes. The University of Tokyo’s Hydra, shown in 2016, has 40 joints driven by 24 linear cylinders and 8 vane motors fed by 36 water-cooled pumps. It is 1.80 m tall and weighs 130 kg. France’s KALYSTA Actuation targets a full electrohydraulic humanoid demonstrator in 2029.
Are EHAs more efficient than electric joints?
Not on published evidence. EHAs avoid valve throttling, and one paper claims over 70% transmission efficiency. Hydra’s linear EHA measured about 40% at peak, and no production humanoid uses EHA joints.
Sources
- H. Kaminaga, J. Ono, Y. Nakashima, Y. Nakamura, Development of Backdrivable Hydraulic Joint Mechanism for Knee Joint of Humanoid Robots, ICRA 2009 (130 mm, 2.0 kg, 1,988 N·m, ~100:1; back-drive torque 3.7/4/14 N·m vs CSG40-100)
- T. Ko, Development of Small and Light-Weight Electro-Hydrostatic Actuators and their Integration to the Whole-Body Drive System of Humanoid Robots, PhD thesis, University of Tokyo, 2018 (Hydra specifications; 1,500 N at 5.25 MPa; 100 Hz pressure bandwidth; ~40% peak efficiency)
- T. Ko, thesis abstract, University of Tokyo
- H. Kaminaga, T. Ko et al., Mechanism and Control of Whole-Body Electro-Hydrostatic Actuator Driven Humanoid Robot Hydra, ISER 2016, Springer 2017
- H. Zhao et al., Design and Experiments of Electro-Hydrostatic Actuator for Wheel-Legged Robot with Fast Force Control Response, Machines 11, 685, 2023 (30 MPa, 9,401 N, 3.69 kg; valve-controlled below 30%, EHA above 70% as stated)
- J. Denis, F. Laberge, J.-S. Plante, A. Girard, Reconfigurable Hydrostatics: Toward Versatile and Efficient Load-Bearing Robotics, Mechatronics 2025
- Université Paris-Saclay, KALYSTA Actuation: towards the first European electrohydraulic humanoid robot, December 2025
- Fluid Power World, Boston Dynamics talks fluid power, 3D printing at IFK, April 2018 (Atlas: 80 kg, 28 DoF, custom servo valves with braking and coasting modes)
- IEEE Robots Guide, Atlas (2016)
- J. Zhang et al., Research Status and Development Trend of Electro-hydrostatic Actuators for Robots, Journal of Mechanical Engineering 61(4), 2025
- Domin, The Future of Humanoid Actuation, October 2025 (supplier view)
